2.
Check Enable Alarm Input Handling.
3.
Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4.
Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
5.
Click Copy to... to copy the
sengs to other alarm input channels.
6.
Click Save.
7.4 Set Excepon Alarm
Excepon such as network disconnecon can trigger the device to take corresponding acon.
Steps
1.
Go to
Conguraon → Event → Basic Event Excepon .
2.
Select Excepon Type.
HDD Full The HDD storage is full.
HDD Error Error occurs in HDD.
Network Disconnected The device is oine.
IP Address Conicted The IP address of current device is same as that of other device in
the network.
Illegal Login Incorrect user name or password is entered.
Voltage Instable The power supply voltage is uctuang.
PT Locking The panning and lng movements are stuck.
3.
Refer to Linkage Method Sengs for seng linkage method.
4.
Click Save.
7.5 Set
Burning-Prevenon
This funcon is used to close the shuer to prevent the lens from high temperature damage.
Steps
1.
Go to
Conguraon → Event → Basic Event Burning-Prevenon .
2.
Check Enable.
3.
Select
burning-prevenon mode.
Lens Movement
The lens move automacally to avoid high temperature damage.
4.
Set the protecon duraon and protecon delay.
5.
Click Save.