Diagnostics
[ Diagnostics > Ports > Port Monitor ]
275
RM GUI GRS
Release
8.0
09/2019
Possible values:
marked
Monitoring is active.
The
Port Monitor
function monitors the data load on the port.
If the device detects a data overload on the port, then the device executes the action
specified in the
Action
column.
On the
Overload detection
tab, specify the parameters to be monitored.
unmarked
(default setting)
Monitoring is inactive.
Link speed/Duplex mode detection on
Activates/deactivates the monitoring of the link speed and duplex mode on the port.
Possible values:
marked
Monitoring is active.
The
Port Monitor
function monitors the link speed and duplex mode on the port.
If the device detects an unpermitted combination of link speed and duplex mode, then the
device executes the action specified in the
Action
column.
On the
Link speed/Duplex mode detection
tab, specify the parameters to be monitored.
unmarked
(default setting)
Monitoring is inactive.
Active condition
Displays the monitored parameter that led to the action on the port.
Possible values:
-
No monitored parameter.
The device does not carry out any action.
Link flap
Too many link changes in the observed period.
CRC/Fragments
Too many CRC/fragment errors in the observed period.
Duplex mismatch
Duplex mismatch detected.
Overload detection
Overload detected in the observed period.
Link speed/Duplex mode detection
Impermissible combination of speed and duplex mode detected.
Action
Specifies the action that the device carries out if the
Port Monitor
function detects that the
parameters have been exceeded.