33. The following message is displayed.
When the disk array is disconnected from the system, the login may fail.
Note: When the iSCSI disk is disconnected, Login fails and Login to
target failed is indicated.
Press Esc. The iSCSI Target Configuration dialog box is displayed.
Confirm whether the iSCSI disk is connected, and then power on the
iSCSI disk or reconnect the cables to the disk.
Move cursor onto the target iSCSI disk line in the iSCSI Target
Configuration dialog box, and then press Delete.
After that, retry from step 30.
34. Press Esc until Controller Selection menu window is displayed. Select
the next port of replaced CNA mezzanine card, and then press Enter.
35. Repeat the procedures, step 22 to step 32.
36. Press Esc for several times until Do you want to exit from the utility
[Y/N]? is prompted, and then press Y.
Server blade reboots.
Configuring Emulex mezzanine card
7-89
Hitachi Compute Blade 500 Series System Service Manual