DKC910IHitachi Proprietary
[INST(IN)14-01-60]
Rev.1.1
INST(IN)14-01-60
Change the SVP mode to Initial Setting. (*3)
(SVP procedure) -- (Execution of New Installation)
(11) Dene the conguration information that you want to install now for this storage system.
(*7)
The conguration information must be dened according to the SVP guidance. Especially, you must not forget the denition
of the following information.
DKC Serial No.
(INST(IN)14-02-90)
(10) Before starting the following procedure, you need to enable the CE mode.
For the procedure for enabling the CE mode, see Setting the jumper used for initial installation (CEMD). (MU02-200)
(12) Connect the LAN cables disconnected at (1)-4, if it is necessary.
(13) Wait till the READY LED is lit and Power Event Log (SYSTEM ON) is reported from all installed
MPs.
(14) STORAGE SYSTEM
ALARM LED lit?
(16) Power Event
Log reported from all installed
MPs?
(15) Perform operations according
to SIM/SSB indications.
(18) Perform operations according
to SIM/SSB indications.
Yes
No
(17) Wait for 40 minutes.
Yes
No
Yes
No