Chapter 5. Creation and Setting of Print Messages
5-32
(10) [Target sensor timer]
● Specifies the time before displaying a fault message when the sensor remains blocked.
● When the sensor blocking time exceeds this value, the [Target Sensor Timer Out] message
appears.
● If the [Target Sensor Timer Out] function is not needed, set the value to "0".
● The setting range is from 1 to 999 (0.1 to 99.9 s).
(11) [Target sensor filter]
● Use this function when you need to continue the operation even if chattering occurs.
* The term "chattering" refers to a state where signal voltage instability occurs when the sensor
signal starts or ends.
● Set the time to ignore any chattering that occurs when the sensor is blocked by the print target.
However, continuous printing does not stop until the sensor filter is completed, so set the sensor
filter setting value as small as possible.
● When a fault occurs due to chattering, the [Print Overlap Fault] message appears.
● If the [Target sensor filter] function is not needed, set the value to "0".
● The setting range is from 1 to 9,999 ms. You can set the time before printing is completed, instead
of the time to ignore.
(12) [Calendar offset]
● Sets whether to use [From today] or [Offset from yesterday] when finding the calendar month or
year offset.
[Calendar offset]