Chapter 12. When Warning or Fault Occurs
12-10
12.2.2. Warning Messages
The following table describes warning messages and their solutions.
Warning message list
Message
No.
Message
Message description
Solution
W-065
Excitation V-ref.
Review
The excitation V-ref. value needs to be
changed.
Find the appropriate excitation V-ref.
value on the [Nozzle test] screen.
(
*1
Technical Manual 5.10)
W-066
Viscosity Reading
Instable
A variation is found in the viscometer
output readings.
Contact your nearest local
distributor.
W-067
Out of Range
An abnormality is found in the
viscometer output readings.
Contact your nearest local
distributor.
W-068
Ink Viscosity High
The ink viscosity is high.
The ink viscosity is being adjusted to
a normal level. If the print quality is
not good, replace the ink.
(
Technical Manual 5.3)
W-069
Ink Viscosity Low
The ink viscosity is low.
The ink viscosity is being adjusted to
a normal level. If the print quality is
not good, replace the ink.
(
Technical Manual 5.3)
W-072
Calendar Content
Inaccurate
The clock is not working properly
because the calendar content is incorrect.
Set the date and time again.
Contact your nearest local
distributor.
-
External
Communication
Error nnn
External communication is not working
properly.
Check the error code and take
appropriate action to prevent the
error from re-occurring.
(Continue to next page)
*1 : Indicates the reference section.

Table of Contents