Chapter 12. When Warning or Fault Occurs
12-8
(2) Faults that do not stop the ink jet
Fault message list (faults that do not stop the ink jet)
Message
No.
Message
Message description
Solution
E-028
Print Data
Changeover Error M
The print data change procedure was
incomplete.
Check the data entered
E-040
External
Communication
Error nnn
The serial communication port had a
data error.
Note the error code and see that no
more errors occur.
(Refer to Communication manual)
E-042
Ink Drop Charge
Too High
The detection level of ink drop charge is
too high.
Clean the gutter, deflection
electrode, and its surroundings.
Check the ink pressure.
(
*1
Technical Manual 5.9)
Adjust the excitation V-ref. value so
that ink drops are produced better.
(
Technical Manual 5.10)
Make sure that the ink stream has
been correctly recovered.
E-043
Barcode Short On
Numbers
The number of characters for the selected
barcode type is insufficient.
Configure the number of barcode to
appropriate value.
(
Technical Manual 8.1)
E-044
Shutdown Fault
The shutdown process failed.
Turn the printer power OFF by main
switch.
E-045
Count Overflow
The calculation result of the count
multiplier overflowed.
Change the count multiplier setting.
E-049
Print Overlap Fault
The next print target detection signal
turned ON before printing was
completed.
Decrease the spacing.
If the print target detection signal is
chattering, use the sensor filter
setting. ( 5.8.1.)
E-050
Print Head Cover
Open
The print head cover is open.
Install the print head cover
E-052
Target Sensor Timer
Out
The print target detector blocking time is
greater than the [Target Sensor Timer]
value.
If the print target is stopped with it
blocking the print target detector,
remove the target.
Change the [Target Sensor Timer]
setting value. ( 5.8.1.)
E-053
Target Spacing Too
Close
The print target detection signal turned
ON five or more times before printing
was started during non-repeat printing.
Move the print target detector closer
to the print head.
E-054
Print Data
Changeover In
Progress S
The unit became [print.-in-progress]
during print data changeover.
Change the [Print data changeover
error] setting to [Disable] in [User
environment setup]. ( 9.1.).
Change the print data changeover
timing or print start timing.
E-056
Blank Print Items
Some print description items are not set.
Change the print description setting.
(Continue to next page)
*1 : Indicates the reference section.