- 24 -
HLP-C
+
Inverters
Parameter and Function List (Part 4)
Function
code
Function
Set Range & Function
Explanation
Factory
Setting
C056 Multi-output DRV 0: Invalid; 1: Ru n; 2:
Fault Sig nal; 3: Zero
Speed; 4: DC Braking
i n d i c a t i o n ; 5 : S e t
Fr e q ue n c y r e a c h; 6:
U n i f o r m F r e q u e n c y
1 r e a ch; 7: U n ifor m
Frequency 2 reach; 8: In
Accel.; 9: In Decel.; 10:
Inverter Overload alarm;
11: M o t o r O v e r lo a d
alarm; 12: Overtorque
detect; 13: Undervoltage
a l a r m ; 1 4 : S i n g l e
stage end; 15: Process
end ; 16: Set Cou nte r
reach; 17: Intermediate
C o u n t e r r e a c h ; 18 :
Exter nally controlled
T i m e r 1 r e a c h ; 19 :
Exter nally controlled
T i m e r 2 r e a c h ; 2 0
4~20mA disconnected;
2 7: D r a w i n g r e a c h ;
28: PI D D ow n Li mit
alarm; 29: PID Up Limit
alarm; 30: Fan run; 31:
Electromagnetic Relay
act; 32: Braking Resistor
act
01
C057
Multi-output
FABC
02
C058 Multi–Analog AM 0~7 0
C059 Analog output gain 0~100 100
C060 Up/down mode 0~1 0
C061 Reserved