- 26 -
HLP-C
+
Inverters
Function
code
Function
Set Range & Function
Explanation
Factory
Setting
C082
St al l pr eventio n
level during decel.
0~200 180
C083
Overtorque detect
level
0~200 000
C084
Overtorque detect
time
0.1~20.0 01.0
C085
Rated Motor Voltage
* 220/380
C086
Rated Motor Current
* *
C087 Motor poles 02~60 04
C088
Rated Motor
Revolution
0~9999 1440
C089
Motor no-load
current
0~100 40
C090 Slip compensation 0~1.0 0.000
C091 DC braking voltage 0.0~20.0 2.0
C092
DC braking time at
starting
0.0~25.0 0.0
C093
DC braking time at
stopping
0.0~25.0 0.0
C094 Speed search time 0.0~20.0 5.0
C095
Speed search
current level
0~200 150
C096
Restart after
instantaneous stop
0~1 0
C097
Allowable power-
off time
0.1~5.0 0.5
C098
Number of
abnormal restart
00~10 00
C099
Auto voltage
regulation function
0:Invalid 1
Effective 1
C100
Auto torgue
compensation
0.0~10.0 2.0
Parameter and Function List (Part 6)