- 82 -
HLP-C
+
Inverters
Fault
Display
Fault
Contents &
Description
Disposal methods
Overcurrent
at constant
speed
C h e c k w h e t h e r t h e i n ve t e r s
capacity is too small and increase its
capacity.
Check whether there is a sudden
change in the power grid voltage.
Overcurrent
at decel
Overcurrent
at stopping
Check whether the insulation of the
output wires is good and whether the
motor has got short circuit.
Extend the deceleration time.
Replace it with an inverter of larger
capacity.
DC braking quantity is too high.
Decrease DC braking quantity.
The inverter has failure. Please send
it to the factory for repair.
Short circuit
to earth
Check whether the connection wire
of the motor has got short circuit.
Check whether the insulation of
the output wires is good.
Please send it for repair.
Overcoltage
at stopping
Overvoltage
at accel
Overvoltage
at constant
speed
Overvoltage
at decel
Extend the deceleration time or add
a braking resistor.
Improve the power grid voltage and
check whether theres is any voltage
leap happened.