Galaxy Dimension Installer Manual
6-143
If selected encryption is enabled for the Primary and Secondary alarm transmission paths. In order for data to
be received when this option is selected the receiver must support decryption.
2 = Remote Access
This option controls encryption for the Remote Servicing sessions. Default is disabled.
0 = Off
If selected encryption is disabled for the Remote Servicing sessions.
1 = On
If selected encryption is enabled for the Remote Servicing sessions. In order for data to be received when this
option is selected the receiver must support decryption.
3 = SIA Control
0 = Off
This option controls encryption for communications between the Ethernet module and remote PC using the
SIA control command protocol. Default is disabled.
1 = On
If selected encryption is enabled for communications between the Ethernet module and remote PC using the
SIA control command protocol. In order for data to be received when this option is selected the receiver must
support decryption.
4 = Alarm Mon.
This option controls encryption for the Alarm Monitoring alarm transmission paths. Default is disabled.
0 = Off
If selected encryption is disabled for the Alarm Monitoring alarm transmission paths.
1 = On
If selected encryption is enabled for the Alarm Monitoring alarm transmission paths. In order for data to be
received when this option is selected the receiver must support decryption.
56.4.10 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the Ethernet module. There are 6 options:
1 = Off; 2 = Ext Telecoms; 3 = Ext RS232; 4 = ISDN; 5 = Int Telecoms; 6 = Int RS232 1.
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals