Galaxy Dimension Installer Manual
6-144
5 = Ext Telecoms
The external telecom module has the same menu structure and function as the internal telecoms with the
following exceptions:
11 Fail to Comm
This is controlled by the number of attempts and not time.
15 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the external telecoms module. There are 6 options:
1 = Off; 2 = Ext RS232; 3 = ISDN; 4 = Ethernet; 5 = Int Telecoms; 6 = Int RS232 1.
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals