EasyManuals Logo

Honeywell Galaxy Dimension series User Manual

Honeywell Galaxy Dimension series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
Galaxy Dimension Installer Manual
5-9
Configuring a MAX
3
Reader into the System
NOTE: MAX
3
readers can only be configured into the Galaxy system from engineer mode.
1. Connect the MAX
3
to the Galaxy control panel as per the instructions given in Figure 5-1.
2. Access engineer mode.
3. Ensure that the Mode is enabled (option 69.1.1 = Access Control.Mode.Enabled).
4. Assign the MAX
3
reader as either On-Line or Stand-Alone using option 69.2.1 = Access
Control.MAX.MAX Address:
0 = On-Line: The MAX
3
is fully integrated with the Galaxy system and communicates via the AB line,
sharing system resources and facilities.
1 = Standalone (default): The MAX
3
operates as an entirely independent unit. The Galaxy does not
monitor the MAX
3
for alarms, tampers or power failure.
5. Press the ent key; the Galaxy panel may prompt (depending on model) for the AB line (1 – 4)) that is
to be searched; select the line and press the ent key. The Galaxy searches for the MAX
3
with the
highest address. New MAX
3
readers are addressed as 8 (standalone) by default.
6. Only if adding a new MAX
3
reader: On locating the MAX
3
address, the keypad prompts for the
OPERATING MODE of MAX
3
to be assigned: select 0 = On-Line or 1 = Standalone as required
and press the ent key.
When 0 = On-Line mode is selected, the keypad displays the current address of the MAX
3
and the
range of valid addresses. Enter the new MAX
3
address and press the ent key; the Galaxy then repro
grams the address of the MAX
3
. The keypad indicates the old and new MAX
3
addresses and the
status of the reprogramming.
NOTE: It is recommended that when adding a reader, it is addressed as the lowest available number on the
line.
7. When the reprogramming is complete the MAX
3
bleeps, the LED’s on the MAX
3
switch off and the
keypad display returns to 1 = MAX Address.
8. Exit engineer mode - engineer code + esc: the keypad displays the message 1 MOD. ADDED -
esc=CONTINUE. LED 2 on the MAX
3
reader switches on. Press the esc key; the keypad
returns to the unset banner.
If this message is not displayed, the MAX
3
reader is not communicating with the control panel
and has not been configured into the system (LED 2 does not switch on).
NOTES:
1. The MAX
3
reader will not operate until engineer mode is exited and the reader is configured into the
system.
2. All MAX
3
doors must be closed, otherwise engineer mode cannot be exited.
9. The on-line MAX
3
reader is now configured into the system.
Access Control (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals