12.2.6 “2-wire Current” Ampliers with Buff-
ered Shunt Cal
Use the following wiring diagram when connecting an amplified
transducer or in-line amplifier with a 2-wire current amplifier to a
High-Level Input channel. Examples of such devices include
• transducerswiththeOption2kinternalamplier(not
equipped with shunt cal)
• transducerswiththeOption2k,3dinternalamplier(buffered
shunt cal)
• ModelU2WUniversalIn-Lineampliers(notequippedwith
shunt cal)
The High-Level Input channel’s Configuration Jumpers must be
set as follows for proper operation. See “Excitation and Signal
Jumpers” on page 56.
• (+)Excitationsupply:“+28Vdc”
• (-)Excitationsupply:“GND”
• Signaltype:“current”
• Signalreference:“singleended”
Figure 12-5: “2-wire Current Amp w/Buffered Shunt Cal” Connection to High-Level Input Channel
1
2
3
4
5
6
7
8
9
10
11
12
(+)EXCITAT ION
SHUNT CAL 1
SHUNT CAL 2
(-)EXCITAT ION
(+)SIGNAL
(-)SIGNAL
(+)ANALOG OUTPUT
(-)ANALOG OUTPUT
N/C
DGND
AUX1
AUX2
DESIGNATION
PIN
CABLE SHIELD CONNECTION SCREW
(+)SUPPLY
SHUNT CAL 1
(+)OUTPUT
IN-LINE AMPLIFIER
CABLE INSTRUMENT CONNECTIONS
(CONNECT TO CABLE SHIELD)
OR
AMPLIFIED TRANSDUCER
SHUNT CAL 2
NOTE: SHUNT CALIBRATION
NOT AVAILABLE ON ALL
DEVICES.
LOOP POWERED,
CURRENT OUTPUT,
DEVICE WITH
NOTE KEYED CONNECTOR
+28V
REMOTE-BUFFERED
SHUNT CAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SC Series and is the answer not in the manual?

Honeywell SC Series Specifications

General IconGeneral
Sensing TechnologyElectrochemical
Target GasCO
Response Time (T90)Varies by gas and sensor type; refer to datasheet for specific values
Expected LifeVaries by sensor type; refer to datasheet for specific values
Measurement RangeVaries by gas and sensor type; refer to datasheet for specific values
ResolutionVaries by gas and sensor type; refer to datasheet for specific values
Response TimeVaries by gas and sensor type; refer to datasheet for specific values
Battery LifeN/A (typically used with external power source)
DimensionsVaries by model; refer to datasheet for specific dimensions
WeightVaries by model
Operating Humidity15% to 95% RH (non-condensing)