Revision 12 ST 700 SmartLine Pressure Transmitters User’s Manual Page 181
13СбрКор
[13RSTCOR]
Calibration Methods
clear all user calibration
adjustments
Press to
enter menu
selection
Press to
initiate action
14№Позиц
[14TAGID]

Character string of device
tag text for display
x = any Alphanumeric value
Press to
enter menu
selection
to select
alphanumeric
character.
to enter
and shift to
the next
character to
the right
15DEV№ПО
[15DEVFW]

Menu item shows the
current Firmware version of
the device. X = any numeric
value
Menu to
select from
list
to enter
16SEN№ПО
[16SENFW]

Menu item shows the
current Firmware version of
the sensor. X = any numeric
value
Menu to
select from
list
to enter
17tдемпф
[17PVDAMP]
##.#
Enter a value for damping of
the device output. Entries
may be any value from 0.00
to 32.00 seconds.
Press to
enter menu
selection
to select
number.
to enter
and shift to
the next digit
to the right
18Ответ
[18FLTSEL]
СтдСкан (STDSOR)
БыстСкн (FASTSOR)
Filter Performance:
Configure the desired
performance for the Output
Speed of Response Filter.
Select from: Standard SOR:
excellent speed of response
to input changes with
optimal noise performance
Fast SOR: fastest speed of
response to input changes
Press to
enter menu
selection
Menu to
select from
list
to enter

Table of Contents