HEATING SYSTEM CONTROL
40 4 213 563 / 03
5.10 Day programs / switching cycles
Day programs are elements which are subordinate to the
week program and contain what are referred to as swit-
ching cycles with corresponding room temperature spe-
cications. You can adapt day programs and switching
cycles to meet your particular requirements. Thus, for
example, the heat output can be reduced for regular and
recurrent periods of absence (e.g. working day) or the
temperature can be specically adapted for presences
with di󰀨erent time periods.
The heating circuit day programs/switching
cycles are independent from the hot water
day programs (5.11 page 51).
The preset day programs with dened swit
-
ching cycles can be adapted and renamed.
The switching cycles of a day program are
only active if the corresponding week pro
-
gram is selected as the basic program.
A maximum of six switching cycles are pos
-
sible for each day program.
5.10.1 Default settings for day programs / swit-
ching cycles
In the factory setting, the names and the switching cycles
of the day programs are predened. Two of these stan-
dard day programs (all day and early & late) are already
assigned to both week programs Week 1 and Week 2.
If you adapt these two day programs to your individual
requirements, you need to consider that both week pro-
grams are also changed (5.5 page 15). You can edit
the default settings listed below as you require (5.10.5
page 45), rename them at any time (5.10.6 page 47)
and reset to the default settings (5.10.7 page 49).
Default settings for day programs
Day programs Switching cycle / temperature Example
All day
from to °C
00:00 06:00 16
06:00 22:00 22
22:00 00:00 16
I work at home and I am present all day.
Longer day
from to °C
00:00 06:00 16
06:00 23:00 22
23:00 00:00 16
I am at home all day and I go to bed later
in the evening.
Early & late
from to °C
00:00 06:00 16
06:00 08:00 22
08:00 16:00 16
16:00 22:00 22
22:00 00:00 16
I go to work at 08:00 hours in the mor-
ning and I do not return home until 17:00
hours in the evening.
Only evening
from to °C
00:00 16:00 16
16:00 23:00 22
23:00 00:00 16
I do not need any heating in the morning
before I set o󰀨 to work. I get back home
at 17:00 hours in the evening.