HEATING SYSTEM CONTROL
534 213 563 / 03
5.11.4 Day programs / switching cycles for hot
water
You can adapt the hot water day programs and switching
cycles to your individual requirements and, in this way,
control the water heating specically for the required time
period and hot water temperature if you use the hot water
on a regular basis, for example.
• The hot water day programs/switching cyc
les are independent from the
day programs (5.10 page 40).
• The preset day programs with dened swit
ching cycles can be adapted and renamed.
•
The switching cycles of a day program are
only active if the corresponding week pro
gram is selected as the basic program.
• A maximum of six switching cycles are pos
sible for each day program.
5.11.5 Default settings for day programs / swit-
ching cycles – hot water
In the factory setting, the names and the switching cycles
of the hot water day programs are predened as with the
heating circuits. Two of these standard day programs (all
day and early & late) are assigned to both week programs
Week 1 and Week 2. If you adapt these two day pro-
grams to your individual requirements, you need to con-
sider that both week programs are also changed (5.11.2
page 52). You can edit the default settings listed below
as you require (5.12.6 page 63), rename them at any
time (5.12.6 page 63) and reset to the default settings
(5.12.6 page 63).
Default settings for day programs – hot water:
Day programs Switching cycle / temperature Example
All day
from to °C
00:00 06:00 45
05:30 22:00 50
22:00 00:00 45
I work at home and I am present all day.
Early & late
from to °C
00:00 05:30 45
05:30 08:00 50
08:00 15:30 45
15:30 22:00 50
22:00 00:00 45
I go to work at 08:00 hours in the mor-
ning and I do not return home until 17:00
hours in the evening.
Only evening
from to °C
00:00 15:30 45
15:30 22:00 50
22:00 00:00 45
I do not need any hot water in the mor-
ning before I set o to work. I get back
home at 17:00 hours in the evening.
All day legio from to °C
00:00 05:30 45
05:30 15:30 50
15:30 16:30 60
16:30 22:00 50
22:00 00:00 45
I work at home and I am present all day.
In addition, the legionella function is ac-
tive (5.11.6 page 54).