115
Table 3 Restrictions on the configuration of RMON
Entry Parameters to be compared
Maximum number of
entries that can be
created
Event
Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)
60
Alarm
Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta), rising
threshold (threshold-value1) and falling threshold (threshold-
value2)
60
Prialarm
Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or
delta), rising threshold (threshold-value1) and falling
threshold (threshold-value2)
50
Displaying and maintaining RMON
To do… Use the command… Remarks
Display RMON statistics
display rmon statistics [ interface-
type interface-number ] [ | { begin
| exclude | include } regular-
expression ]
Available in any view
Display the RMON history control
entry and history sampling
information
display rmon history [ interface-
type interface-number ] [ | { begin
| exclude | include } regular-
expression ]
Available in any view
Display RMON alarm
configuration information
display rmon alarm [ entry-
number ] [ | { begin | exclude |
include } regular-expression ]
Available in any view
Display RMON prialarm
configuration information
display rmon prialarm [ entry-
number ] [ | { begin | exclude |
include } regular-expression ]
Available in any view
Display RMON events
configuration information
display rmon event [ entry-
number ] [ | { begin | exclude |
include } regular-expression ]
Available in any view
Display log information for the
specified or all event entries.
display rmon eventlog [ entry-
number ] [ | { begin | exclude |
include } regular-expression ]
Available in any view