EasyManua.ls Logo

HP 5820X Switch - Detecting Pds; Enabling the PSE to Detect Nonstandard Pds; Configuring a PD Disconnection Detection Mode

HP 5820X Switch
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88
To do… Use the command… Remarks
3. Enable PoE for the PoE
interface.
poe enable
Required.
Disabled by default.
4. Configure a description for the
PD connected to the PoE
interface.
poe pd-description text
Optional.
By default, no description for the
PD connected to the PoE interface
is available.
Detecting PDs
Enabling the PSE to detect nonstandard PDs
Two types of PDs are available: standard PDs and nonstandard PDs. The PSE can only detect standard
PDs and supply power to them. The PSE can only detect nonstandard PDs and supply power to them after
the PSE is enabled to detect nonstandard PDs.
To enable the PSE to detect nonstandard PDs:
To do…
Use the command… Remarks
1. Enter system view.
system-view
2. Enable the PSE to detect
nonstandard PDs.
poe legacy enable pse pse-id
Required.
By default, the PSE can detect
standard PDs rather than non
standard PDs.
Configuring a PD disconnection detection mode
To detect the PD connection with PSE, PoE provides two detection modes: AC detection and DC detection.
The AC detection mode is energy saving relative to the DC detection mode.
To configure a PD disconnection detection mode:
To do…
Use the command… Remarks
1. Enter system view.
system-view
2. Configure a PD disconnection
detection mode.
poe disconnect { ac | dc }
Optional.
The default PD disconnection
detection mode is ac.
CAUTION:
If you change the PD disconnection detection mode when the device is running, the connected PDs will
be powered off. Be cautious to do so.