381
[SwitchE] pim ipv6
[SwitchE-pim6] c-bsr 1003::2 128 20
[SwitchE-pim6] c-rp 1003::2 group-policy 2005
[SwitchE-pim6] quit
4. Verify the configuration.
Use the display pim ipv6 interface command to view the IPv6 PIM configuration and running status on
each interface. For example:
# View the IPv6 PIM information on all interfaces of Switch A.
[SwitchA] display pim ipv6 interface
Interface NbrCnt HelloInt DR-Pri DR-Address
Vlan100 0 30 1 1001::1
(local)
Vlan101 1 30 1 1002::2
Vlan102 1 30 1 1003::2
To view the BSR election information and the locally configured C-RP information in effect on a switch,
use the display pim ipv6 bsr-info command. For example:
# View the BSR information and the locally configured C-RP information in effect on Switch A.
[SwitchA] display pim ipv6 bsr-info
Elected BSR Address: 1003::2
Priority: 20
Hash mask length: 128
State: Accept Preferred
Uptime: 00:04:22
Expires: 00:01:46
# View the BSR information and the locally configured C-RP information in effect on Switch D.
[SwitchD] display pim ipv6 bsr-info
Elected BSR Address: 1003::2
Priority: 20
Hash mask length: 128
State: Elected
Uptime: 00:05:26
Expires: 00:01:45
Candidate BSR Address: 4002::1
Priority: 10
Hash mask length: 128
State: Candidate
Candidate RP: 4002::1(Vlan-interface105)
Priority: 192
HoldTime: 130
Advertisement Interval: 60
Next advertisement scheduled at: 00:00:48
# View the BSR information and the locally configured C-RP information in effect on Switch E.
[SwitchE] display pim ipv6 bsr-info
Elected BSR Address: 1003::2
Priority: 20

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A5500 SI Switch Series and is the answer not in the manual?

HP A5500 SI Switch Series Specifications

General IconGeneral
Layer SupportLayer 2 and Layer 3
MAC Address Table16K entries
Routing ProtocolRIP, OSPF, BGP, IS-IS
ManagementWeb, CLI, SNMP
Input Voltage100-240 V AC
Operating Temperature0°C to 45°C
Ports48 x 10/100/1000 ports, 4 x 10-Gigabit SFP+ ports
Dimensions440 x 430 x 44 mm
Weight5.5 kg
Operating Humidity10% to 95% (non-condensing)

Related product manuals