# On Switch D, configure the service scope of RP advertisements, and configure VLAN-interface 104 as
a C-BSR and C-RP of admin-scope zone 2.
[SwitchD] pim ipv6
[SwitchD-pim6] c-bsr scope 4
[SwitchD-pim6] c-bsr 3002::2
[SwitchD-pim6] c-rp 3002::2 scope 4
[SwitchD-pim6] quit
# On Switch F, configure VLAN-interface 109 as a C-BSR and C-RP in the global scope zone.
<SwitchF> system-view
[SwitchF] pim ipv6
[SwitchF-pim6] c-bsr scope global
[SwitchF-pim6] c-bsr 8001::1
[SwitchF-pim6] c-rp 8001::1
[SwitchF-pim6] quit
5. Verify the configuration.
To view the BSR election information and the C-RP information on a switch, use the display pim ipv6 bsr-
info command. For example:
# View the BSR information and the locally configured C-RP information on Switch B.
[SwitchB] display pim ipv6 bsr-info
Elected BSR Address: 8001::1
Priority: 64
Hash mask length: 126
State: Accept Preferred
Scope: 14
Uptime: 00:01:45
Expires: 00:01:25
Elected BSR Address: 1002::2
Priority: 64
Hash mask length: 126
State: Elected
Scope: 4
Uptime: 00:04:54
Next BSR message scheduled at: 00:00:06
Candidate BSR Address: 1002::2
Priority: 64
Hash mask length: 126
State: Elected
Scope: 4
Candidate RP: 1002::2(Vlan-interface101)
Priority: 192
HoldTime: 130
Advertisement Interval: 60
Next advertisement scheduled at: 00:00:15
# View the BSR information and the locally configured C-RP information on Switch D.
[SwitchD] display pim ipv6 bsr-info

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A5500 SI Switch Series and is the answer not in the manual?

HP A5500 SI Switch Series Specifications

General IconGeneral
Layer SupportLayer 2 and Layer 3
MAC Address Table16K entries
Routing ProtocolRIP, OSPF, BGP, IS-IS
ManagementWeb, CLI, SNMP
Input Voltage100-240 V AC
Operating Temperature0°C to 45°C
Ports48 x 10/100/1000 ports, 4 x 10-Gigabit SFP+ ports
Dimensions440 x 430 x 44 mm
Weight5.5 kg
Operating Humidity10% to 95% (non-condensing)

Related product manuals