398
[SwitchC-pim6] bidir-pim enable
# On Switch D, enable IPv6 multicast routing, enable IPv6 PIM-SM on each interface, enable MLD on
VLAN interface 300, and enable IPv6 BIDIR-PIM.
<SwitchD> system-view
[SwitchD] multicast ipv6 routing-enable
[SwitchD] interface vlan-interface 300
[SwitchD-Vlan-interface300] mld enable
[SwitchD-Vlan-interface300] pim ipv6 sm
[SwitchD-Vlan-interface300] quit
[SwitchD] interface vlan-interface 400
[SwitchD-Vlan-interface400] pim ipv6 sm
[SwitchD-Vlan-interface400] quit
[SwitchD] interface vlan-interface 103
[SwitchD-Vlan-interface103] pim ipv6 sm
[SwitchD-Vlan-interface103] quit
[SwitchD] pim ipv6
[SwitchD-pim6] bidir-pim enable
[SwitchD-pim6] quit
3. Configure C-BSR and C-RP.
# On Switch C, configure VLAN interface 102 as a C-BSR, and loopback interface 0 as a C-RP for the
entire IPv6 BIDIR-PIM domain.
[SwitchC-pim6] c-bsr 2002::2
[SwitchC-pim6] c-rp 6001::1 bidir
[SwitchC-pim6] quit
4. Verify the configuration.
To view the DF information of IPv6 BIDIR-PIM on a switch, use the display pim ipv6 df-info command:
# View the DF information of IPv6 BIDIR-PIM on Switch A.
[SwitchA] display pim ipv6 df-info
RP Address: 6001::1
Interface State DF-Pref DF-Metric DF-Uptime DF-Address
Vlan100 Win 100 2 01:08:50 FE80::200:5EFF:
FE71:2800 (local)
Vlan101 Lose 100 1 01:07:49 FE80::20F:E2FF:
FE38:4E01
# View the DF information of IPv6 BIDIR-PIM on Switch B.
[SwitchB] display pim ipv6 df-info
RP Address: 6001::1
Interface State DF-Pref DF-Metric DF-Uptime DF-Address
Vlan200 Win 100 1 01:24:09 FE80::200:5EFF:
FE71:2801 (local)
Vlan101 Win 100 1 01:24:09 FE80::20F:E2FF:
FE38:4E01 (local)
Vlan102 Lose 0 0 01:23:12 FE80::20F:E2FF:
FE15:5601
# View the DF information of IPv6 BIDIR-PIM on Switch C.

Table of Contents