EasyManuals Logo

HP A5500 SI Switch Series User Manual

HP A5500 SI Switch Series
443 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
51
[SwitchB-radius-scheme2] user-name-format without-domain
[SwitchB-radius-scheme2] quit
# Create an ISP domain domain2; reference scheme2 for the authentication, authorization, and
accounting of LAN users; specify domain2 as the default ISP domain.
[SwitchB] domain domain2
[SwitchB-isp-domian2] authentication lan-access radius-scheme scheme2
[SwitchB-isp-domian2] authorization lan-access radius-scheme scheme2
[SwitchB-isp-domian2] accounting lan-access radius-scheme scheme2
[SwitchB-isp-domian2] quit
[SwitchB] domain default enable domain2
# Globally enable 802.1X and then enable it on GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3
respectively.
[SwitchB] dot1x
[SwitchB] interface gigabitethernet 1/0/2
[SwitchB-GigabitEthernet1/0/2] dot1x
[SwitchB-GigabitEthernet1/0/2] quit
[SwitchB] interface gigabitethernet 1/0/3
[SwitchB-GigabitEthernet1/0/3] dot1x
[SwitchB-GigabitEthernet1/0/3] quit
4. Configure the RADIUS server
On the RADIUS server, configure the parameters related to Switch A and Switch B. For more
information, see the configuration guide of the RADIUS server.
5. Verify the configuration
After the configurations, the two multicast sources and hosts initiate 802.1X authentication. After passing
authentication, Source 1 sends multicast flows to 224.1.1.1 and Source 2 sends multicast flows to
224.1.1.2; Host A sends messages to join multicast groups 224.1.1.1 and 224.1.1.2. Use the display
igmp-snooping group command to display information about IGMP snooping groups. For example:
# Display the information of the IGMP snooping groups in VLAN 100 on Switch B.
[SwitchB] display igmp-snooping group vlan 100 verbose
Total 1 IP Group(s).
Total 1 IP Source(s).
Total 1 MAC Group(s).
Port flags: D-Dynamic port, S-Static port, C-Copy port
Subvlan flags: R-Real VLAN, C-Copy VLAN
Vlan(id):100.
Total 1 IP Group(s).
Total 1 IP Source(s).
Total 1 MAC Group(s).
Router port(s):total 1 port.
GE1/0/1 (D) ( 00:01:30 )
IP group(s):the following ip group(s) match to one mac group.
IP group address:224.1.1.1
(0.0.0.0, 224.1.1.1):
Attribute: Host Port
Host port(s):total 1 port.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A5500 SI Switch Series and is the answer not in the manual?

HP A5500 SI Switch Series Specifications

General IconGeneral
Layer SupportLayer 2 and Layer 3
MAC Address Table16K entries
Routing ProtocolRIP, OSPF, BGP, IS-IS
ManagementWeb, CLI, SNMP
Input Voltage100-240 V AC
Operating Temperature0°C to 45°C
Ports48 x 10/100/1000 ports, 4 x 10-Gigabit SFP+ ports
Dimensions440 x 430 x 44 mm
Weight5.5 kg
Operating Humidity10% to 95% (non-condensing)

Related product manuals