Chapter 4
Memory Extender Board Upgrade Procedures
Introduction
60
Step 6. Install the front bezel. See “Installing the Front Bezel” on page 16.
Step 7. If rack mounted, slide the hp Server into the rack until it stops.
Verification of Upgrade Installation
After completing the upgrade, verify that the sever is ready for operation as follows:
Step 1. Reconnect AC power to rear panel connectors.
Step 2. Press the front panel power switch to power on the server.
Step 3. Wait for completion of the power-on-self-test. Verify that no errors have been detected.
Step 4. At the EFI/OS selection, select the EFI shell and enter the Info Mem command. Verify that all
installed memory is recognized and is operating correctly.
Step 5. Initiate the OS and monitor operation. Check for error messages. Check the System Event Log for
erroneous system events