HP StorageWorks 8/20q Fibre Channel Switch Command Line Interface Guide 259
show port
Description Displays operational information for one or more ports.
Authority None
Syntax
show port
Table 64 describes the information returned by the show port command.
Table 64 Show port display entries
Parameter Description
AdminState Administrative state
AIinit Number of times the port begins arbitrated loop initialization
AIinitError Number of times the port entered initialization and the initialization
failed
AsicNumber Application-specific integrated circuit (ASIC) number
AsicPort ASIC port number
BadFrames Number of frames that have framing errors.
BBCR_FrameFailures Number of times more frames were lost during a credit recovery period
than the recovery process could resolve. This causes a Link Reset to
recover the credits.
BBCR_RRDYFailures Number of times more Receiver_Ready (R_RDY) primitives were lost
during a credit recovery period than the recovery process could resolve.
This causes a Link Reset to recover the credits.
ClassXFramesIn Number of class x frames received by this port
ClassXFramesOut Number of class x frames sent by this port
ClassXWordsIn Number of class x words received by this port
ClassXWordsOut Number of class x words sent by this port
ClassXToss Number of times an SOFi3 or SOFn3 frame is tossed
ConfigType Configured port type: G, GL, F, FL, TR, or Donor
DecodeError Number of decode errors detected
POSTFaultCode Fault code from the most recent power-on self test
POSTStatus Status from the most recent power-on self test
DownstreamISL Downstream ISL state. True indicates a connection to another switch
that is not the principal switch.
EpConnects Number of times an E_Port connected through ISL negotiation
EpConnState E_Port connection status
EpIsoReason E_Port isolation reason
FBusy Number of times the switch sent a fabric busy (F_BSY) frame because
the Class 2 frame could not be delivered within ED_TOV time; or the
number of class 2 and class 3 F_BSY frames generated by this port in
response to incoming frames. This usually indicates a busy condition on
the fabric or N_Port that is preventing delivery of this frame.