EasyManuals Logo

HP StorageWorks 8/20q Command Line Interface Guide

HP StorageWorks 8/20q
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
HP StorageWorks 8/20q Fibre Channel Switch Command Line Interface Guide 47
The restore process replaces all configuration information on the switch and afterwards the switch is
automatically reset. If the restore process changes the IP address, all management sessions are terminated.
Use the set setup system command to return the IP configuration to the values you want. To restore
the switch, open a Telnet session (a new IP address may be required), then enter the config restore
command from in an Admin session, as shown in the following example:
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #> config restore
The switch will be reset after restoring the configuration.
Please confirm (y/n): [n] y
Alarm Msg: [day month date time year][A1005.0021][SM][Configuration is being
restored - this could take several minutes]
Alarm Msg: [day month date time year][A1000.000A][SM][The switch will be reset
in 3 seconds due to a config restore]
8/20q FC Switch (admin) #>
Alarm Msg: [day month date time year][A1000.0005][SM][The switch is being reset]
Paging a switch
To help you locate a particular switch in a rack of switches, you can turn on the beacon feature with the
set beacon command. This causes all port Logged-In LEDs to flash in unison. The following is an
example of how to turn the beacon on and off:
8/20q FC Switch #> set beacon on
8/20q FC Switch $> set beacon off
Managing the date and time
The switch date and time can be set explicitly using the date command or it can be set automatically
through a Network Time Protocol (NTP) server. The date command also displays the current time. Unlike
the date command, the NTP server also synchronizes the date and time on the switch with the date and
time on the workstation, which is required for SSL connections.
NOTE: To set the date with the date command, the switch NTP client must be disabled. For information
about disabling the NTPClientEnabled parameter, see ”set setup system” (page 221).
If you use the date command, you can set the time zone using the set timezone command. The default
time zone is Universal Time (UTC), also known as Greenwich Mean Time (GMT). Changing the time zone
converts the current time to the time in the new time zone. For this reason, if you are not using an NTP
server, set the time zone first, then set the date and time.
Displaying the date and time
To display the date and time, enter the date command, as shown in the following example:
8/20q FC Switch #> date
Mon Apr 07 07:51:24 2008

Table of Contents

Other manuals for HP StorageWorks 8/20q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 8/20q and is the answer not in the manual?

HP StorageWorks 8/20q Specifications

General IconGeneral
BrandHP
ModelStorageWorks 8/20q
CategorySwitch
LanguageEnglish

Related product manuals