EasyManuals Logo

HP StoreFabric SN6500B User Manual

HP StoreFabric SN6500B
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
Fabric OS Administrator’s Guide 131
53-1002745-02
Frame Redirection
4
Example of creating a frame redirect zone
The following example creates a redirect zone, given a host (10:10:10:10:10:10:10:10), target
(20:20:20:20:20:20:20:20), virtual initiator (30:30:30:30:30:30:30:30), and virtual target
(40:40:40:40:40:40:40:40):
switch:admin>zone --rdcreate 10:10:10:10:10:10:10:10 20:20:20:20:20:20:20:20 \
30:30:30:30:30:30:30:30 40:40:40:40:40:40:40:40 restartable noFCR
Deleting a frame redirect zone
Use the following procedure to delete a frame redirect zone:
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the zone
--rdDelete command to remove the base redirect zone object,
“red_______base”.
NOTE
When the base zone is removed, the redirect zone configuration “r_e_d_i_r_c__fg” is removed
as well.
3. Enter the cfgSave command to save changes to the defined configuration.
Example of deleting a frame redirect zone
switch:admin> zone --rddelete \
red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20
Viewing frame redirect zones
Use the following procedure to view frame redirect zones:
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the cfgShow command.

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals