Fabric OS Administrator’s Guide 501
53-1002745-02
End-to-end performance monitoring
20
Access Gateway considerations for Advanced Performance Monitoring
EE monitors and frame monitors are supported on switches in Access Gateway mode. Top Talker
monitors are not supported on these switches.
EE monitors must be installed on F_Ports. Frame monitors can be installed on F_Ports or N_Ports.
Refer to the Access Gateway Administrator’s Guide for additional information.
End-to-end performance monitoring
Use end-to-end (EE) monitoring when you want to monitor throughput between a pair of devices.
End-to-end performance monitoring counts the number of words in Fibre Channel frames for a
specified Source ID (SID) and Destination ID (DID) pair.
To enable EE performance monitoring, you must configure an EE monitor on a port, specifying the
SID-DID pair (in hexadecimal). The monitor counts only those frames with a matching SID and DID.
Each SID or DID has the following three fields:
• Domain ID (DD)
• Area ID (AA)
• AL_PA (PP)
For example, the SID 0x118a0f denotes DD 0x11, AA 0x8a, and AL_PA 0x0f.
An EE monitor includes these counts:
• RX_COUNT - Words in frames received at the port
For frames received at the port with the EE monitor installed, the RX_COUNT is updated if the
frame SID is the same as the SID in the monitor and the frame DID is the same as the DID in
the monitor.
• TX_COUNT - Words in frames transmitted from the port
For frames transmitted from the port with the EE monitor installed, TX_COUNT is updated if the
frame DID is the same as the SID in the monitor and the frame SID is the same as the DID in
the monitor.
Maximum number of EE monitors
The maximum number of end-to-end monitors supported varies depending on the switch model:
• The Brocade DCX 8510, 6505, 6510, and 6520 models allow up to 512 end-to-end monitors
shared by all ports in the same ASIC. Also, these models allow up to 256 end-to-end monitors
per port.
• The Brocade DCX, DCX-4S, 5100, 8000, VA-40FC, and Brocade Encryption Switch models
allow up to 1024 end-to-end monitors shared by all ports in the same ASIC. Also, these models
allow up to 256 end-to-end monitors per port.
• The Brocade 300, 5300, 5410, 5424, 5430, 5450, 5460, 5470, 5480, and 7800 models
allow up to 768 end-to-end monitors shared by all ports in the same ASIC. Also, these models
allow up to 192 end-to-end monitors per port.
The number of interswitch links (ISLs) configured on the switch affects the amount of resources
available for end-to-end monitors.

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals