392 Fabric OS Administrator’s Guide
53-1002745-02
Disabling bottleneck detection on a switch
13
Disabling bottleneck detection on a switch
When you disable bottleneck detection on a switch, all bottleneck configuration details are
discarded, including the list of excluded ports and non-default values of alerting parameters.
Use the following procedure to disable bottleneck detection:
1. Connect to the switch and log in using an account with admin permissions.
2. Enter the bottleneckmon --disable command to disable bottleneck detection on the switch.
switch:admin> bottleneckmon --disable
Example of disabling bottleneck detection on a switch
switch:admin> bottleneckmon --disable
switch:admin> bottleneckmon --status
Bottleneck detection - Disabled