EasyManua.ls Logo

HP StoreFabric SN6500B

HP StoreFabric SN6500B
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fabric OS Administrator’s Guide 387
53-1002745-02
Changing bottleneck detection parameters
13
Congestion threshold for alert - 0.700
Averaging time for alert - 200 seconds
Quiet time for alert - 150 seconds
Per-port overrides for alert parameters:
========================================
Port Alerts? LatencyThresh CongestionThresh Time (s) QTime (s)
=================================================================================
46 N -- -- -- --
47 L 0.750 -- 200 150
Example 5: Changing the latency time value for a single port
This changes the time value to 250 seconds for port 47 only. Notice that the command must
include -alert=latency to preserve the latency-only alerts configured in the previous example.
In general, -alert must be specified (with =latency or =congestion if desired), on every --config
command when alerts are desired.
switch:admin> bottleneckmon --config -alert=latency -time 250 47
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000
Switch-wide alerting parameters:
================================
Alerts - Yes
Latency threshold for alert - 0.200
Congestion threshold for alert - 0.700
Averaging time for alert - 200 seconds
Quiet time for alert - 150 seconds
Per-port overrides for alert parameters:
========================================
Port Alerts? LatencyThresh CongestionThresh Time (s) QTime (s)
=================================================================================
46 N -- -- -- --
47 L 0.750 -- 250 150
Example 6: Clearing bottleneck detection override values from ports
This removes any changed bottleneck detection parameter values from ports 46 and 47.
Notice that the “Per-port overrides for alert parameters” section is not displayed as there are no
per-port overrides.
switch:admin> bottleneckmon --configclear 46-47
switch:admin> bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide sub-second latency bottleneck criterion:
====================================================
Time threshold - 0.800
Severity threshold - 50.000

Table of Contents

Other manuals for HP StoreFabric SN6500B