414 Fabric OS Administrator’s Guide
53-1002745-02
Working with EX_Ports
14
QOS Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port ON
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
Fault Delay: 0(R_A_TOV)
NPIV PP Limit: 255
CSCTL mode: OFF
D-Port mode: OFF
Compression: OFF
Encryption: ON
FEC: ON
myswitch:admin>
Example Enabling compression on port 1 of ‘myswitch’
The subsequent portCfgShow command shows both encryption and compression to be enabled on
the port.
myswitch:admin> portdisable 1
myswitch:admin> portcfgcompress --enable 1
myswitch:admin> portenable 1
myswitch:admin> portcfgshow 1
Area Number: 1
Octet Speed Combo: 1(16G|8G|4G|2G)
Speed Level: AUTO(SW)
AL_PA Offset 13: OFF
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port ON
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
Fault Delay: 0(R_A_TOV)
NPIV PP Limit: 255
CSCTL mode: OFF
D-Port mode: OFF
Compression: ON
Encryption: ON
FEC: ON
myswitch:admin>
Example Setting the secret key for the front phantom wwn projected by the FCR on the ‘edge’ switch
Use portCfgExPort EX_Port# on the remote FCR to learn the front phantom switch wwn value.