EasyManuals Logo

HP StoreFabric SN6500B User Manual

HP StoreFabric SN6500B
666 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #584 background imageLoading...
Page #584 background image
584 Fabric OS Administrator’s Guide
53-1002745-02
Inter-fabric link configuration
24
Hash Algorithm: N/A
Edge fabric's primary wwn: N/A
Edge fabric's version stamp: N/A
This port can now connect to another switch.
The following example configures an EX_Port for connecting to a Brocade Network OS fabric.
The -m 5 option indicates Network OS connectivity.
switch:admin> portcfgexport 1/5 -a 1 -f 15 -m 5
switch:admin> portcfgexport 1/5
Port 1/5 info
Admin: enabled
State: NOT OK
Pid format: Not Applicable
Operate mode: Brocade NOS
Edge Fabric ID: 15
(output truncated)
For related FC-FC routing commands, refer to fcrEdgeShow, fcrXlateConfig, fcrConfigure, and
fcrProxyConfig in the Fabric OS Command Reference.
A Fibre Channel router can interconnect multiple fabrics. EX_Ports or VEX_Ports attached to
more than one edge fabric must configure a different fabric ID for each edge fabric.
3. (Optional) Configure FC router port cost if you want to change the default values. For
information about using FC router port cost operations, refer to “FC router port cost
configuration” on page 587.
4. (Optional) Set up ISL or EX_Port trunking. For information on trunking setup, refer to
“Configuring EX_Port trunking” on page 542.
5. Enter the portEnable command to enable the ports that you disabled in step 1.
switch:admin> portenable 7/10
6. Physically attach ISLs from the Fibre Channel router to the edge fabric.
7. Enter th e portCfgShow command to view ports that are persistently disabled.
FC ports on the Brocade 7800 switches and FX8-24 blades are configured as persistently
disabled by default, to avoid inadvertent fabric merges when installing a new FC router.
switch:admin> portcfgshow 7/10
Area Number: 74
Speed Level: AUTO
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
EX Port ON
Mirror Port ON
FC Fastwrite ON

Table of Contents

Other manuals for HP StoreFabric SN6500B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StoreFabric SN6500B and is the answer not in the manual?

HP StoreFabric SN6500B Specifications

General IconGeneral
BrandHP
ModelStoreFabric SN6500B
CategorySoftware
LanguageEnglish

Related product manuals