If only one SSD is being installed, install the SSD in port 1.
a. Insert the SSD into the M.2 slot at a 45° angle.
b. Carefully press the SSD down to the horizontal position.
c. Install the SSD mounting screw.
d. If you are installing a second SSD, repeat steps a–c.
10. Connect the SATA cable to enablement board.
11. Install the M.2 enablement board.
12. Install the riser cage.
13. Connect the SATA cable to system board according to the label indication.
14. Install the access panel.
15. Install the server into the rack.
16. Connect all peripheral cables to the server.
17. Connect each power cord to the server.
18. Connect each power cord to the power source.
19. Power up the server on page 43.
20. If removed, install the front bezel.
The installation is complete.
To configure the M.2 SATA SSDs, see the HPE Smart Array SR Gen10 Configuration Guide at the
Hewlett Packard Enterprise website.
Processor heatsink assembly option
Processor cautions
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
Hardware options installation 83