The installation is complete.
Installing the NVMe drive cage in the LFF chassis
This option only can be installed in box 1.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• Flat-headed screwdriver
• T-10 Torx screwdriver
Procedure
1. If installed, remove the front bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Do one of the following:
•
Extend the server from the rack.
• Remove the server from the rack.
6. Remove the access panel.
7. Remove the air baffle.
8. Install the NVMe drive cage.
a. Use flat-head screwdriver to pry the two box 1 fillers.
Hardware options installation 65