CAUTION: If installing a processor with a faster speed, update the system ROM before installing
the processor.
To download firmware and view installation instructions, see the Hewlett Packard Enterprise
Support Center website.
CAUTION: THE CONTACTS ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to
the socket or processor, do not touch the contacts.
CAUTION: To prevent mechanical damage or depositing oil on your hands or other contamination,
hold the heatsink only by the edge of its base plate. Do not touch the heatsink fins.
Installing the processor heatsink assembly
Prerequisites
Before installing this option, ensure that you have the following:
The components included with the hardware option kit
T-30 Torx screwdriver
Procedure
1. Identify the processor, heatsink, and socket module components.
2. Review the processor cautions.
3. If installed, remove the front bezel.
4. Power down the server.
5. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
6. Disconnect all peripheral cables from the server.
7. Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
8. Remove the access panel.
9. Remove the air baffle.
10. Install the processor heatsink assembly:
a. Locate and align the Pin 1 indicator on the processor frame and the socket.
b. Align the processor heatsink assembly with the heatsink alignment posts and gently lower it down
until it sits evenly on the socket.
The heatsink alignment posts are keyed. The processor will only install one way.
84 Hardware options installation