External device issues
Video issues
Screen is blank for more than 60 seconds after powering up the server
Symptom
The screen is blank for more than 60 seconds after the server is powered up.
Cause
The monitor is not receiving power.
The monitor is not cabled properly.
The monitor cables are not connected properly.
The power is not sufficient for a PCIe device or graphics controller installed on the server.
A video expansion board is installed, but is not powered or configured properly.
A video expansion board installed on the server is not supported.
The video drive is not current.
Action
1. Verify that the monitor power cord is plugged into a working grounded (earthed) AC outlet.
2. Power up the monitor and be sure that the monitor light is on, indicating that the monitor is receiving
power.
3. Verify that the monitor is cabled to the intended server or KVM connection.
4. Check the cable connection from the monitor to the server, and then from the server to the power outlet.
5. Press any key, or enter the password, and wait for the screen to activate to be sure the energy-saver
feature is not in effect.
6. Verify that a PCIe device or graphics controller does not need additional power to operate. For more
information, see the device documentation.
7. Verify that a video expansion board has not been added to replace onboard video, which would make it
seems as if the video is not working.
Disconnect the video cable from the onboard video. Then, reconnect it to the video jack on the expansion
board. All servers automatically bypass onboard video when a video expansion board is present.
8. Press any key, or enter the password, and wait for the screen to activate to verify that the power-on
password feature is not in effect.
You can also tell if the power-on password is enabled if a key symbol is displayed on the screen when
POST completes.
If you do not have access to the password, disable the power-on password using the Security menu of the
Aptio Setup Utility.
Monitor does not function properly with energy saver features
Symptom
The monitor does not function properly with energy saver features.
Cause
The monitor does not support energy saver features.
44 External device issues

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE ProLiant MicroServer Gen10 Series and is the answer not in the manual?

HPE ProLiant MicroServer Gen10 Series Specifications

General IconGeneral
Product LineHPE ProLiant MicroServer
ProcessorAMD Opteron X3000 Series
Memory Slots2
Networking2x 1GbE ports
MemoryUp to 32 GB DDR4 UDIMM
Storage4 LFF SATA HDD bays (3.5-inch)
RAID SupportRAID 0, 1
Power Supply200W non-redundant power supply
ManagementHPE iLO 5 Standard
Form FactorMicro Tower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
WeightApprox. 6.5 kg