Chapter 6 Function Introduction Shenzhen Hpmont Technology Co., Ltd
104 HD30 Series Inverters User Manual
No. Name Description Range
factory setting
F16.19 AO1 terminal output function selection 0
19
1
F16.20
AO2 terminal output function selection
0190
F16.21 High-speed pulse output function selection 0
19
0
0: Reversed.
1,2: Output frequency, reference frquency (0maximum output frequency)
3: Motor RPM (0maximum output frequency corresponding to RPM).
4: Output current (0twice motor’s rated current).
5: Output current (0twice motor’s rated current).
69: Reversed.
10: Output torque (03 times motor’s rated torque).
11: Output voltage (01.2 times inverters rated voltage).
12: Bus voltage (02.2 times inverters rated voltage).
13: Output power (0twice motor’s rated power).
14: AI1 input (010V).
15: AI2 input (-1010V / 020mA).
16: AI3 input (-1010V / 020mA).
17: AI4 input (-1010V / 020mA).
18,19: Output frequency, reference frequency (- 1 times1 times maximum output frequency).

Table of Contents

Other manuals for hpmont HD30 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD30 Series and is the answer not in the manual?

hpmont HD30 Series Specifications

General IconGeneral
Brandhpmont
ModelHD30 Series
CategoryInverter
LanguageEnglish

Related product manuals