Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual -143-
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
content
d00.53 Actual length 0-65535m
*
d00.54 Total length 0-65535km
*
d00.55 Total time at power-on 0-65535h
*
d00.56 Total time at operation 0-65535h
*
d00.57
High bit of motor total
energy consumption
0-65535k kW.h
*
d00.58
Low bit of motor total
energy consumption
0.0-999.9kW.h
*
d00.59
High bit of energy con.
at this time running
0-65535k kW.h
*
d00.60
Low bit of energy con.
at this time running
0.0-999.9kW.h
*
d00.61 Present fault
1-100
100: means undervoltage
*
Group F00 Basic Parameter (refer to pages 59
62)
F00.00 Reserved
F00.01 Control mode selection
0: V/f control without PG
1: Reserved
2: Vector control without PG
0 1 ×
F00.02 Inverter type setting
0: G type
1: P type
0 1 ×
F00.03 Motor selection
0: Motor 1
1: Motor 2
0 1 ×
F00.04
HD30 general
extension option
selection
0: Option is invalid
1: HD30-EIO is valid
2: Reserved
3: HD30-PIO is valid
0 1 ×
F00.05
HD30 extension
application function
0: No extension application 0 1 ×
F00.06
Inverter max. output
frequency
50.00-400.00Hz 50.00Hz 0.01Hz ×
F00.07
Upper limit of operation
frequency setting
source
0: Digital setting (F00.08)
1: Analogue input AI setting
2: Terminal pulse setting
0 1 ×
F00.08
Upper limit of operation
frequency
0.00-F00.06 50.00Hz 0.01Hz ×
F00.09
Lower limit of operation
frequency
0.00-upper limit 0.00Hz 0.01Hz ×
F00.10
Frequency setting
sources selection
0: Display panel digital
setting
1: Terminal digital setting
2: SCI communication setting
0 1 ×
A