Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd
―144― HD30 Series Inverters User Manual
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
3: AI analogue setting
4: Terminal pulse setting
F00.11
Command setting
source selection
0: Display panel running
source
1: Terminal running source
2: SCI communication
running source
0 1 ×
F00.12
Function selection of
the multi-function key
0: Switch the display panel
running direction
1: Switch local and remote
control
2: Multi-function key is invalid
2 1 ○
F00.13
Starting frequency
digital setting
0.00-upper limit 50.00Hz 0.01Hz ○
F00.14
UP/DOWN digital
setting control
Units: Frequency setting
save selection at power
outage
0: Frequency setting will not
be saved at power outage
1: Frequency setting will be
saved to F00.13 at power
outage
Tens: Frequency setting
control selection at stop
0: Frequency setting will not
be restored to F00.13 at stop
1: Frequency setting will be
restored to F00.13 at stop
Hundreds: Communication
setting frequency storage
selection
0: Do not save when power
is off.
1: Save to F00.13 when
power is off.
Thousands: Switch the
frequency channel to the
analogue selection
0: Do not save
1: Save the frequency set by
display pane
1001 1 ×
F00.15
Jog operation
frequency digital
setting 1
0.00-upper limit 5.00Hz 0.01Hz ○