EasyManuals Logo

hpmont MONT20 User Manual

hpmont MONT20
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Chapter 5 Function Introduction
34 MONT20 User Manual V1.6
Ref. Code Function Description Setting Range [Default]
F06.25 Auxilliary parameter 3 00000 - 11111 [00000]
Unit: OD signal keeping when first time power up under distance control
0: Do not keep.
1: Keep. When first time power up under distance control and DO command keeps for more than 2.5s, if DO
command is cancelled and not received complete OD signal, door motor will keep open. It will not close
until fully OD signal outputs.
Ten: Address setting under CAN control
0: Front door.
1: Rear door.
Hundred: Electric angle search for permanent magnet Syn. motor (PMSM)
0: Current method.
1: Pulse method.
Thousand: Motor overload protection shield
0: No shield.
1: Shield.
Ten thousand: OD abnormal shutdown protection open
0: Open.
During the opening process of the motor, if it detects that the door is blocked for more than 10 times in
total, and the complete OD signal is not detected, it will alarm E0010 (OD abnormal fault).
After the fault, the motor stops for 20 minutes and the fault is automatically reset.
1: Not open.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont MONT20 and is the answer not in the manual?

hpmont MONT20 Specifications

General IconGeneral
Brandhpmont
ModelMONT20
CategoryController
LanguageEnglish

Related product manuals