Appendix A Parameter
60 MONT20 User Manual V1.6
R
ef. Code
Function Setting Range Default Attribute
Setting
d01.10 Input terminal status 2
Unit - ten correspond to OD and CD
0: Terminal disconnects with common
terminal
1: Terminal connects with common terminal
Actual *
d01.11 Output terminal status
Unit - hundred corresponds to DOA, DCA and
PA
0: Terminal disconnects with common
terminal
1: Terminal connects with common terminal
Actual *
d01.12 Factory debug parameter
d01.13 Z signal pulse 00000 - 65535 Actual *
d01.14
Z signal correction pulse
deviation
00000 - 65535 Actual *
d01.15 Z signal correction error times 00000 - 65535 Actual *
d01.16
Z signal Max. correction
deviation
00000 - 65535 Actual *
d01.17 Encoder counter 00000 - 65535 Actual *
d01.18 - d01.29 Factory debug parameter
d01.30 U phase zero offset 00000 - 65535 Actual *
d01.31 V phase zero offset 00000 - 65535 Actual *
d01.32 W phase zero offset 00000 - 65535 Actual *
d01.33 - d03.39 Factory debug parameter
F00: Basic Parameter, on page 23
F00.00 Users password 00000 - 65535 0
F00.01 Parameter batch selection
0: Invalid, set parameters manually
1: Restore to default parameter
2: Clear fault information
3: Unused
4: Upload parameter to external keypad
5: Download parameter from external keypad
to MONT20
6: Restore customer customized parameter of
Syn. motor
7: Restore customer customized parameter 2
of Syn. motor
8, 9: Unused
10: Restore customized speed control
parameter of customer Asyn. motor
0
×