Set Business IP to XXX.XXX.XXX.XXX, Subnet mask to 255.255.254.0, Gateway IP to
XXX.XXX.XXX.XXX. The values here are examples. The actual values prevail.
Set NAT IP to VCN external IP address, which is the same as the external IP address mapped from
the VCN internal IP address displayed on the ECC800.
4. Configure the NTP synchronization. After setting The NTP clock source server to Yes,
set the IP address of the NTP server.
The server that connects to cameras needs to enable the camera NTP synchronization function. For the
detailed operations, see Step 2.
Step 2 Enabling camera NTP synchronization.
The camera NTP synchronization function for the server is disabled by default. The camera
NTP synchronization function needs to be enabled for the server that connects to cameras.
After the camera NTP synchronization function is enabled, cameras will automatically
time-synchronize from their access servers.
1. Log in to the OMU portal of the VCN as the Admin user.
2. Choose Maintenance > Unified Configuration.
3. Select the server that the camera needs to access, set Module name to SCU and
Parameter type to System property, and click Search.
Figure 6-20 Configuring Camera NTP Synchronization
4. In the search results, click Edit in the row where Parameter Name is NTPIPC and set
Value to 1.
5. Click Save. After the camera NTP synchronization function is enabled, the camera, after
being connected to the server, will automatically time-synchronize with the server.
----End
Follow-up Procedure
The VCN automatically restarts after the IP address is modified. The restart takes about 5
minutes. After the restart, use the new IP address to access the VCN.
Change the PC IP address to an address in the network segment of the new VCN IP
address, enter the VCN IP address in the address box of the Internet browser, and log in
to the OMU Portal system.
(Optional) Deploying IVS in Stack Mode. For details, log in to the
https://e.huawei.com/, search for the VCN product documentation, open the
documentation, and see the section (Optional) Deploying IVS in Stack Mode.

Table of Contents

Other manuals for Huawei FusionModule800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei FusionModule800 and is the answer not in the manual?

Huawei FusionModule800 Specifications

General IconGeneral
BrandHuawei
ModelFusionModule800
CategoryStorage
LanguageEnglish

Related product manuals