FusionModule800 Smart Small Data Center
V100R021C00
User Manual
Issue 01
Date 2021-02-05
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei FusionModule800

Questions and Answers

  • T
    taylortraceySep 12, 2025
    What to do if the compressor does not work in Huawei Server?
    • E
      evanslauraSep 12, 2025
      If the compressor does not work in your Huawei Server, check the high and low pressure switches, the main circuit breaker, fuses, and cables. Also, check if the compressor motor or driver is damaged, and verify the requirement status on the LCD.
  • J
    Joel FreyAug 25, 2025
    What to do if Huawei FusionModule800 fan air intake and exhaust vents are blocked?
    • A
      Alexis LynnAug 25, 2025
      If the fan air intake and exhaust vents are blocked, clear any obstacles that are causing the blockage.
  • B
    Brittany BrownAug 25, 2025
    How to fix Huawei FusionModule800 Storage outdoor unit not secured to the floor?
    • M
      michelle71Aug 26, 2025
      To fix an outdoor unit that is not secured to the floor, tighten the screws that secure the rack to the floor.
  • Z
    zevansSep 23, 2025
    What does it mean when the alarm indicator (yellow) is blinking on Huawei Server?
    • C
      clarkjoshuaSep 23, 2025
      If the alarm indicator (yellow) is blinking on your Huawei Server, it indicates a PSU communication failure. Clean the connector in the rear of the faulty PSU. If the fault persists, replace the ECC800 subrack.
  • M
    Michael HicksSep 13, 2025
    What to do if Huawei Server UPS cabinet generates abnormal noise or smell?
    • D
      Dawn HolmesSep 13, 2025
      If you notice abnormal noise or smell in the Huawei Server UPS cabinet, shut down the UPS and cut off the power input immediately. Contact your local Huawei technical support.
  • R
    Richard FernandezSep 18, 2025
    Why does the compressor generate too much noise in my Huawei Server?
    • R
      Robert LopezSep 18, 2025
      If the Huawei Server's compressor generates too much noise, add refrigerant oil.
  • C
    Crystal HughesSep 6, 2025
    What to do if the ATS controller screen cannot be turned on for Huawei Server?
    • M
      Matthew RobinsonSep 6, 2025
      To troubleshoot a Huawei Server where the ATS controller screen cannot be turned on, check that the cable terminal on the top of the controller has been inserted, power off the ATS upstream for 5 minutes and restart the controller, and replace the controller if the fuse inside is damaged.
  • S
    Sandy BaileySep 7, 2025
    Why is humidity high in the Huawei Server equipment room?
    • D
      David SmithSep 7, 2025
      If you are experiencing high humidity or condensation in the equipment room with your Huawei Server, ensure that the doors, windows, floors, and ceilings are properly sealed. If the outdoor humidity is too high, shut down the fresh air system. Also, ensure the data center's air aisle doors or control skylights are open, or the filler panels of some server cabinets are opened. Use cold aisle containment to control humidity and add extra dehumidifiers if necessary.
  • V
    Victor JonesSep 23, 2025
    Why does the LCD display nothing on my Huawei Server?
    • J
      Jeremy WagnerSep 23, 2025
      If the mains switch is ON but the LCD displays nothing on your Huawei Server, check the UPS input power cable connection.
  • G
    Gary MelendezAug 30, 2025
    How to fix a Huawei Server ATS that won't switch automatically?
    • A
      Alexandra HaynesAug 30, 2025
      To resolve the issue of a Huawei Server's ATS not switching automatically, check that the power is normal, clear all ATS alarms, set the ATS to automatic mode, remove the ATS handle, check that the terminal output is 220 V using a multimeter (and if abnormal, check the upstream input circuit breaker), replace the blown control loop fuse, and set the switching delay, closing the automatic switch to O.

Huawei FusionModule800 Specifications

General IconGeneral
ModelFusionModule800
Form FactorModular
Power SupplyDual Hot-swappable Power Supplies
Cooling SystemIn-row cooling or room-level cooling
Power DensityHigh Power Density
Deployment TimeLess than 1 week
Energy EfficiencyHigh Energy Efficiency
Humidity Range5% to 90% (non-condensing)
AltitudeUp to 3000 meters