FusionModule800 Smart Small Data Center
Installation Guide (Six Fans)
3 Hardware Installation
Copyright © Huawei Technologies Co., Ltd.
128
Figure 3-118 Installing a VCN500
Step 4 Connect the VCN500 power cable to the appropriate PDU2000.
----End
3.11.4 Installing the VCN540
Context
The VCN540 does not carry disks when being delivered. First install disks and then
install the device in a network cabinet.
After the VCN540 is delivered to the site, disk filler panels are installed in slots where
disks are not installed, by default. You are not advised to remove the filler panels from
the slots where disks are not installed, because removing the filler panels will affect the
heat dissipation of fans and generate some noises.
Procedure
Step 1 Install a hard drive.
1. Install a hard drive.
2. Secure the hard drive to the front panel using a screwdriver.
3. Push the hard drive into the subrack along the guide rails until it cannot move forwards.
4. Close the ejector lever and push the hard drive in position.