Data Plan
Table 17-7 provides the OLT data plan, and Table 17-8 provides the ONU data plan.
Table 17-7 Data plan for configuring automatic transmission of power distribution site
information in the electrical power system over Ethernet-OLT side
Device Item Data
OLT_A Uplink port 0/19/0
VLAN Inband management VLAN: smart VLAN 8
Service VLAN (SVLAN): smart VLAN 200
(used for transmitting the site information about
the electrical power system)
SVLAN: smart VLAN 101 (used for transmitting
GOOSE packets)
Inband management IP
address
192.168.50.20/24
GPON service board
The GPON service board can
be an H801GPBC,
H802GPBD, or H805GPBD
board.
Port: 0/3/1
ONU ID: 1
ONU authentication mode: SN
ONU SN: 48575443E6D8B541
DBA profile Profile name: Data
Type: type3
Assured bandwidth: 20 Mbit/s
Maximum bandwidth: 50 Mbit/s
ONU line profile
l Profile ID: 10, bound to the DBA profile
named Data
l GEM port ID: 0 (used for transmitting inband
management service stream)
l GEM port ID: 1 (used for transparently
transmitting the information about the
electrical power system)
l GEM port ID: 2 (used for transparently
transmitting GOOSE packets)
l T-CONT ID: 5
ONU management mode
SNMP
Priority The 802.1p priority is used: The priority of the
site information about the electrical power system
is 1 and the priority of GOOSE packets is 6.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 17 Electrical Service Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1833