Item Data
ESC
l SN: 0
l Sub-node: 30
l Name: H303ESC
MG interface data
l mgid: 0
l code: text
l transfer: udp
l protocol: H.248
l Port ID: MG; 2944; MGC: 2944
l domainname: UA5000.com
l Stand-alone digitap: 1234xxxx
l Escape bucket digitmap: 110|119|999
IP address
l Media IP address of MG interface 0 of the UA5000: 10.10.10.2/24
l Signaling IP address of MG interface 0 of the UA5000:
10.10.10.4/24
l IP address of the MGC: 10.10.20.1/24
The following displays the commands that need to be included in the script according to the
preceding data plan.
CAUTION
Each command in the script must end with a carriage return (CR).
enable
config
emu add 1 fan 0 6 FAN
interface emu 1
fan speed mode automatic
quit
emu add 0 h303esc 0 30
interface h248 0 y
if-h248 attribute mgip 10.10.10.2 mgport 2944 code text
transfer udp domainName UA5000.com mgcip_1 10.10.20.1 mgcport_1 2944
mg-media-ip 10.10.10.4
digitmap set inner 1234xxxx emergency 110|119|999
reset coldstart y
quit
save
A.3 Operation Guide on Battery Supplementary Charge
Based on the battery features, automatic discharge may occur due to chemical reactions during
the delivery and storage. In this case, the battery capacity and the open circuit voltage decrease.
To restore the voltage and capacity of the battery completely, perform the supplementary charge
before using the battery.
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI A Additional Information
Issue 04 (2012-06-25) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
117