4.2 Commissioning the MG Interface
This topic describes how to commission the MG interface. The MG interface is an interface for
the communication between the UA5000 and the MGC. This interface can use the H.248 or
MGCP protocol. Before commissioning the service, you must commission the MG interface
successfully.
4.2.1 Commissioning the MG Interface (Through H.248)
This topic describes how to commission the MG interface so that the MG interface can
communicate with the MGC through the H.248 protocol normally.
Prerequisites
l The UA5000 must work in the normal state.
l The IP address used in the example must be configured in the IP address pool through the
ip address command.
l The data on the MGC, that is, the data corresponding to the data on the MG, and the data
on the MG interface must be configured correctly.
l The system must be configured with the H.248 protocol.
l If the versions supported by the softswitch and the UA5000 are consistent, you need not
configure the negotiated version. If the versions supported by the softswitch and the
UA5000 are inconsistent, you need to run the if-h248 attribute command to configure the
H.248 protocol for the MG interface to negotiate the version.
Networking
Figure 4-3 shows the networking for commissioning the MG interface through the H.248
protocol.
Figure 4-3 Networking for commissioning the MG interface through the H.248 protocol
UA5000
MGC
10.10.20.1/24
Router
10.10.10.1/24
H.248
P
V
M
B
A
S
L
0/11 0/12
A
S
L
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI 4 Commissioning the Interconnection
Issue 04 (2012-06-25) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
99