NOTE
The UA5000 supports the independent upstream transmission and the integrated upstream transmission
modes. This commissioning task uses the independent upstream transmission mode. To use the integrated
upstream transmission mode, run the working mode command to set the working mode of the PVMB
board as the integrated upstream transmission mode.
Data Plan
Table 4-3 provides the data plan for commissioning the MG interface through the H.248
protocol.
Table 4-3 Data plan for commissioning the MG interface through the H.248 protocol
Item Data
MG interface mgid 0
protocol H.248
code text
transfer UDP
port 2944
domainname ua5000.com
IP address IP address of MG0 on the
UA5000
10.10.10.2/24
Media IP address of MG0 on the
UA5000
10.10.10.2/24
Default gateway of MG0 on the
UA5000
10.10.10.1/24
MGC data IP address of the MGC 10.10.20.1/24
port 2944
protocol H.248
code text
transfer UDP
Procedure
Step 1 Add an MG interface.
huawei(config)#interface h248 0
Are you sure to add MG interface?(y/n)[n]:y
huawei(config-if-h248-0)#
Step 2 Configure the parameters of the MG interface.
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI 4 Commissioning the Interconnection