Index type MacAddress
--------------------------------------------------
0 Active 00-E0-FC-33-44-56
1 Active 02-E0-FC-02-02-03
3. Configure the IP address of the outband network port, gateway, and VLAN
information.
huawei(config)#interface outband
huawei(config-outband)#ip address 10.20.1.2 255.255.255.0 10.20.1.1
vlan_tag 1001
4. Configure the working mode.
huawei(interface-outband)#quit
huawei(config)#sysman mode outband
5. Configure the community name and the access authority.
huawei(config)#snmp-agent community read public
huawei(config)#snmp-agent community write private
6. Enable the trap sending.
huawei(config)#snmp-agent trap enable standard
7. Configure the trap destination host name, IP address, and trap sending parameter list
name.
huawei(config)#snmp-agent target-host trap-hostname public address
10.10.1.10 trap-paramsname public
huawei(config)#snmp-agent target-host trap-paramsname public v2c
securityname public
8. Save the data.
huawei(config)#save
l Configure the outband NMS on the iManager U2000 side.
1. Set the following parameters on the iManager U2000.
IP address: 10.10.1.1
GET community name: public
SET community name: private
2. Configure the route gateway to network section 10.20.1.0/24 as 10.10.1.10.
NOTE
When the IP address of the UA5000 outband NMS interface is not in the same subnet as the
IP address of the iManager U2000, you need to configure the route information to forward the
NMS packet.
----End
Result
You can maintain and manage the device through the iManager U2000.
4.1.2 Commissioning the Inband NMS
This topic describes how to verify that the UA5000 can realize the inband management through
the uplink port (the inband management interface) so that the iManager U2000 can maintain the
device through this management channel.
Networking
In the independent upstream mode, the iManager U2000 connects to the inband NMS interface
ETH1 on the UA5000 through the IP network, as shown in Figure 4-2.
UA5000 Universal Access Unit Product
Commissioning Guide-PVM CLI 4 Commissioning the Interconnection
Issue 04 (2012-06-25) Huawei Proprietary and Confidential