Procedure
Step 1 Add an MG interface.
huawei(config)#interface mgcp 0
Are you sure you want to add MG interface?(y/n)[n]:y
huawei(config-if-mgcp-0)#
Step 2 Configure the parameters of the MG interface.
huawei(config-if-mgcp-0)#if-mgcp attribute mgip 10.10.10.2 mgport 2427 domainName
ua5000.com mgcip_1 10.10.20.1 mgcport_1 2727
Step 3 Restart the MG interface.
huawei(config-if-mgcp-0)#reset
Are you sure to reset MG interface?(y/n)[n]:y
huawei(config-if-mgcp-0)#quit
Step 4 Save the data.
huawei(config)#save
----End
Result
Run the display if-mgcp all command to query the status of the MG interface, and find that the
status is in the normal state.
4.3 Commissioning the Interconnection with the SIP
Interface
This topic describes how the UA5000 as the voice over IP gateway (VGW) communicates with
the IMS through the SIP interface.
Prerequisites
l The voice protocol supported by the system must be configured to SIP.
NOTE
You can run the display protocol support command to query the current voice protocol type. If the
voice protocol is not SIP, do as follows:
l When the control board is PVMD, run the protocol support command to switch the voice
protocol to SIP.
l When the control board is PVMB, run the load program command and load data command to
re-load the host program and the database file (corresponding to the SIP protocol), and then run
the reboot command to restart the system to switch the voice protocol to SIP.
l The UA5000 must be in the normal state.
l The IP address (signaling IP address and media IP address) of the SIP interface must exist
in the corresponding IP address pool. You can run the ip address command to configure
the IP address of the SIP interface.
l After the configuration, you must run the reset(sip) command to reset the SIP interface to
make the configuration data take effect. Otherwise, the configuration data is stored only in
the database.